Welcome to the FireLite ANN-80 User Manual, a comprehensive guide for understanding and operating the ANN-80 series of fire annunciators. This manual provides detailed insights into the features, installation, configuration, and troubleshooting of these devices, ensuring safe and effective use. Designed for technical personnel and end-users, it serves as an essential resource for maintaining fire safety systems.

1.1 Overview of the FireLite ANN-80 Series

The FireLite ANN-80 Series is a line of compact, backlit LCD remote fire annunciators designed for use with compatible Fire Alarm Control Panels (FACPs). The series includes models such as the ANN-80, ANN-80-W, and ANN-80C, each offering unique features tailored for specific applications. These annunciators mimic the FACP display, providing real-time system status updates, including device type, alarm, trouble, or supervisory conditions. They support custom alpha labels for enhanced clarity and are ideal for installations requiring remote monitoring of fire safety systems. The ANN-80 Series is known for its reliability, ease of use, and compliance with industry standards like NFPA 72.

1.2 Importance of the User Manual

The FireLite ANN-80 User Manual is an essential resource for understanding and effectively utilizing the ANN-80 Series Annunciators. It provides detailed instructions for installation, configuration, and operation, ensuring users can maximize the device’s capabilities while maintaining safety and compliance. The manual serves as a reference guide for troubleshooting common issues, reducing downtime and enhancing system reliability. By following the manual’s guidelines, users can ensure proper setup and ongoing maintenance, critical for fire safety systems. It is a vital tool for both initial deployment and long-term management of the ANN-80 Series, helping users navigate its features and ensure optimal performance.

1.3 Target Audience

The FireLite ANN-80 User Manual is designed for individuals involved in the installation, configuration, and maintenance of fire safety systems. This includes fire alarm technicians, system installers, and facility managers responsible for ensuring compliance with safety standards. The manual is also beneficial for end-users seeking to understand the operation and functionality of the ANN-80 Series Annunciators. Additionally, it serves as a reference for engineers and technical personnel who need detailed specifications and troubleshooting guidance. By catering to a diverse audience, the manual ensures that all stakeholders can effectively utilize the ANN-80 Series to uphold fire safety and system efficiency.

Features of the FireLite ANN-80 Series

The FireLite ANN-80 Series offers a compact, backlit 80-character LCD display, mimicking FACP systems. It supports custom alpha labels, system status indicators, and zone assignments for enhanced functionality and user clarity.

2.1 Key Features of the ANN-80 Series

The FireLite ANN-80 Series features a backlit 80-character LCD display, providing clear visibility of system status, alarms, troubles, and supervisory conditions. It supports custom alpha labels for detailed point identification and zone assignments, enhancing user understanding. The annunciator communicates seamlessly with compatible FACPs via the ANN-BUS, ensuring real-time system updates. Its compact design allows for flexible installation options, including wall or electrical box mounting. Additionally, the ANN-80 Series is equipped with control switches for system acknowledgment and silencing, making it a versatile and user-friendly solution for fire alarm management. These features ensure efficient monitoring and response to fire-related events.

2.2 Differences Between ANN-80, ANN-80-W, and ANN-80C Models

The ANN-80, ANN-80-W, and ANN-80C models offer distinct features tailored to specific applications. The ANN-80 is the standard base model, providing essential functionalities for fire alarm monitoring. The ANN-80-W includes additional weather-resistant capabilities, making it suitable for outdoor or harsh environments. The ANN-80C serves as a specialized indicator, designed for advanced system integration and custom configurations. While all models share core functionalities like backlit LCD displays and ANN-BUS connectivity, the ‘W’ and ‘C’ variants cater to specialized needs, ensuring flexibility for diverse installation requirements and operational demands.

2.3 Custom Alpha Labels and Zone Assignments

The FireLite ANN-80 series supports custom alpha labels and zone assignments, allowing users to tailor the system to their specific needs. Custom alpha labels enable clear identification of zones, devices, or points, improving readability and response times. Zone assignments permit logical organization of fire alarm systems, ensuring that each zone is easily identifiable; These features enhance system clarity and efficiency, enabling quick identification of alarms or troubles. Users can program these settings during configuration, ensuring that the system aligns with their facility’s layout and operational requirements. This customization capability is a key advantage of the ANN-80 series, providing flexibility for diverse applications.

Installation of the FireLite ANN-80 Series

Installing the FireLite ANN-80 Series requires careful planning, proper mounting, and wiring in accordance with NFPA 72 standards. Ensure compatibility with your Fire Alarm Control Panel (FACP) system.

3.1 Pre-Installation Requirements

Before installing the FireLite ANN-80 Series, review the user manual thoroughly to understand system specifications and compatibility. Ensure the device is compatible with your Fire Alarm Control Panel (FACP) and verify all necessary components are available. Check local and NFPA 72 regulations for compliance. Confirm the operating voltage and wiring requirements match your setup. Ensure the ANN-BUS connection is properly planned and compatible with the FACP. Gather all required tools and materials, such as mounting hardware and wiring. Finally, ensure power is disconnected before starting installation to avoid damage or safety hazards.

3.2 Step-by-Step Installation Guide

Mount the annunciator on a wall or in an electrical box, ensuring it is level and securely fastened. Connect the wiring to the FACP, adhering to NFPA 72 standards and local codes. Configure the ANN-BUS settings as specified in the user manual. Power on the device and test all functions, including alarm acknowledgment and zone indicators. Verify proper communication with the FACP and ensure all custom labels are displayed correctly. Perform a final inspection to confirm installation meets safety and regulatory requirements. Refer to the manual for detailed diagrams and specific wiring instructions to ensure a successful setup.

3.3 Wiring and Mounting Options

The FireLite ANN-80 series offers flexible wiring and mounting options to suit various installation needs. Wire the device using compatible cable types, ensuring connections are secure and meet NFPA 72 standards. Mount the annunciator in a standard electrical box or directly on the wall using provided hardware. For multiple units, use the ANN-BUS connection to simplify wiring between devices. Ensure proper grounding and power supply connections to avoid malfunctions. Flush or surface mounting options are available, depending on the installation environment. Refer to the manual for specific wiring diagrams and mounting instructions to ensure compliance with safety and regulatory requirements.

Configuration and Programming

This section guides you through configuring and programming the ANN-80 series, including custom alpha labels, zone assignments, and setting up the ANN-BUS connection for seamless operation.

4.1 Configuring the ANN-80 Series

Configuring the ANN-80 series involves setting up the remote fire annunciator to communicate with the Fire Alarm Control Panel (FACP). Use DIP switches to configure settings like baud rate and node ID. The ANN-80 mimics the FACP display, showing system status, device type, and custom alpha labels. Connect the annunciator via the ANN-BUS, ensuring compatibility with the FACP. Refer to the wiring diagram for proper connections. Up to eight ANN-80 units can be connected to the FACP. Ensure all configurations comply with NFPA 72 standards for fire safety systems. Proper configuration ensures accurate system monitoring and reliable performance.

4.2 Programming Custom Alpha Labels

Programming custom alpha labels for the ANN-80 series allows for clear identification of zones, devices, and system points. These labels, up to , are programmed through the Fire Alarm Control Panel (FACP) and then displayed on the ANN-80 annunciator. Use a PC or programming interface to assign descriptive text to zones or points, ensuring easy recognition during alarms or troubles. Labels must be programmed in the FACP before they appear on the ANN-80. Refer to the FACP manual for specific programming instructions. Properly configured labels enhance system clarity and response efficiency, ensuring quick identification of events. Testing labels post-programming is recommended.

4.3 Setting Up the ANN-BUS Connection

The ANN-BUS connection enables communication between the ANN-80 series and the Fire Alarm Control Panel (FACP). To set it up, use a shielded twisted-pair cable to connect the annunciator to the FACP. Ensure the wiring adheres to NFPA 72 standards and local codes. The ANN-BUS supports up to eight N-ANN-80 devices, each requiring a unique address configured via DIP switches. After wiring, verify communication by checking the FACP’s event log for successful connection messages. Proper setup ensures seamless system integration and accurate alarm reporting. Refer to the FACP manual for specific wiring and configuration details.

Operation and Functionality

The ANN-80 series features an LCD display showing real-time system status, including device type, alarms, troubles, and supervisory conditions. It supports custom alpha labels for enhanced clarity.

5.1 Understanding the LCD Display

The ANN-80 series features a backlit 80-character LCD display, divided into four lines of each. This screen mimics the Fire Alarm Control Panel (FACP) display, providing real-time status updates. The LCD shows device types, active alarms, trouble conditions, and supervisory zones. Custom alpha labels can be programmed to enhance clarity, making it easier to identify specific points. The display is easy to read, even in low-light conditions, thanks to its backlight. This feature ensures quick recognition of system events, aiding in timely responses during emergencies. The LCD’s clear layout simplifies monitoring and managing fire safety systems effectively.

5.2 System Status Indicators and Annunciator Functions

The FireLite ANN-80 series includes system status indicators that provide visual alerts for alarms, troubles, and supervisory conditions. These indicators help users quickly identify system events. The annunciator functions enable real-time monitoring of fire alarm systems, displaying detailed information such as device type, zone assignments, and custom alpha labels. The system offers control switches for acknowledging alarms and silencing audible signals, ensuring efficient management of fire safety events. These features enhance situational awareness and streamline response processes, making it easier to address system issues promptly and effectively. The clear indicators and intuitive functions ensure reliable operation and compliance with fire safety standards.

5.3 Acknowledging Alarms and Troubles

Acknowledging alarms and troubles on the FireLite ANN-80 is essential for effective system management. The annunciator features control switches that allow users to acknowledge active alarms and troubles, ensuring proper response to system events. Once acknowledged, the system provides visual confirmation, and audible signals can be silenced if equipped. Proper acknowledgment prevents false alarms and ensures timely resolution of issues. Users must understand the procedure to avoid miscommunication or system malfunctions. This process is critical for maintaining fire safety and operational efficiency, ensuring all events are addressed promptly and correctly. Regular training is recommended to familiarize personnel with these functions. Compliance with NFPA standards is assured through proper acknowledgment protocols.

Troubleshooting the FireLite ANN-80 Series

Troubleshooting the FireLite ANN-80 Series involves identifying common issues like error codes or display malfunctions. The user manual provides diagnostic procedures and reset instructions to address these problems. Regular maintenance and consulting the manual or technical support can resolve most issues efficiently.

6.1 Common Issues and Solutions

Common issues with the FireLite ANN-80 Series include display malfunctions, communication errors, and incorrect zone labeling. Display issues may arise from loose connections or faulty LCD panels, requiring a reset or replacement. Communication errors often occur due to improper wiring or ANN-BUS configuration, which can be resolved by verifying connections and settings. Incorrect zone labels typically result from programming errors and can be fixed by reprogramming custom alpha labels. For detailed troubleshooting steps, refer to the diagnostic procedures outlined in the manual. Regular maintenance and adherence to NFPA 72 standards can prevent many of these issues. Always consult the manual for specific solutions.

6.2 Error Codes and Diagnostic Procedures

The FireLite ANN-80 Series displays specific error codes to identify system issues. Common codes include E01 (communication failure), E02 (power supply issue), and E03 (zone configuration error). To diagnose, check the ANN-BUS connection for E01, ensure proper power supply for E02, and verify zone programming for E03. Use the LCD display to identify the error and follow the manual’s troubleshooting guide; Reset the device if necessary and ensure all wiring meets NFPA 72 standards. If issues persist, refer to the detailed diagnostic procedures or contact technical support for further assistance. Regular maintenance can help prevent recurring errors.

6.3 Resetting the Annunciator

To reset the FireLite ANN-80 annunciator, press and hold the “Ack” button for 10 seconds until the LCD display shows “Resetting…”. Release the button and wait for the process to complete. The device will revert to factory defaults, clearing all custom settings. After resetting, reconfigure the device as needed, including custom labels and zone assignments. Perform a system test to ensure proper functionality. If issues persist, consult the manual or contact technical support for further assistance. Regular resets can help maintain system performance and resolve recurring errors effectively.

Maintenance and Upkeep

Regularly clean the LCD display and inspect wiring connections to ensure optimal performance. Schedule periodic firmware updates to maintain system compatibility and functionality. Follow guidelines for proper upkeep.

7.1 Regular Maintenance Tips

Regular maintenance is crucial for ensuring the FireLite ANN-80 operates efficiently. Clean the LCD display with a soft cloth and mild detergent to avoid dust buildup. Inspect wiring connections periodically to prevent corrosion or loose contacts. Schedule firmware updates to keep the system up-to-date with the latest features and security patches. Additionally, check the annunciator’s backlit display for proper illumination and replace any faulty LEDs as needed. Refer to the user manual for specific guidelines on cleaning and updating procedures to maintain optimal performance and compliance with safety standards.

7.2 Cleaning the LCD Display

To maintain the FireLite ANN-80’s LCD clarity, clean it regularly using a soft, dry microfiber cloth. For stubborn smudges, dampen the cloth with distilled water or a mild detergent solution, avoiding direct liquid contact with the screen. Never use harsh chemicals, abrasive cleaners, or paper towels, as they may damage the display. Turn off the device before cleaning and wipe gently in one direction. Avoid touching the LCD with bare hands to prevent fingerprints. For best results, clean the display when it is on to easily spot smudges. Regular cleaning ensures optimal visibility and performance of the annunciator.

7.3 Firmware Updates

Regular firmware updates are essential to ensure the FireLite ANN-80 operates with the latest features and security patches. To update the firmware, visit the Honeywell website or authorized distributor for the newest version. Download the update file and transfer it to the device using the ANN-BUS connection or a compatible programming tool. Follow the manual’s step-by-step instructions to initiate the update process. Ensure the device is powered on and connected during the update to prevent interruptions. Never use unverified firmware sources, as they may damage the system. Firmware updates are typically performed by authorized personnel to maintain system integrity and performance.

Technical Specifications

The FireLite ANN-80 Series operates on 18.8VDC to 38.2VDC, with a maximum current consumption of 1.5mA. It features an 80-character backlit LCD display for clear visibility.

8.1 Operating Voltage and Current Requirements

The FireLite ANN-80 Series requires an operating voltage of 18.8VDC to 38.2VDC, with a maximum current consumption of 1.5mA. Proper wiring must adhere to NFPA 72 standards, ensuring safe and reliable operation. The device is designed to function efficiently within these voltage parameters, maintaining clear LCD display performance. It is essential to use a compatible power supply to avoid malfunctions. Refer to the FACP manual for wiring distance limitations and gauge recommendations. Compliance with local electrical codes is mandatory for installation. Environmental conditions, such as temperature and humidity, must align with specifications to ensure optimal performance and longevity of the annunciator.

8.2 Display and Communication Specifications

The FireLite ANN-80 Series features a backlit, 80-character LCD display, arranged in per line over four lines. It mimics the Fire Alarm Control Panel (FACP) display, showing system status, device type, alarms, troubles, and custom alpha labels. Communication occurs via the ANN-BUS, enabling seamless integration with compatible FACPs. The annunciator supports remote monitoring and control, with clear visual indicators for system acknowledgment. Wiring requirements and distance limitations are detailed in the FACP manual, ensuring proper installation. The display’s clarity and communication capabilities ensure reliable performance, making it a robust solution for fire safety systems.

8.4 Compliance with NFPA 72 Standards

The FireLite ANN-80 Series adheres strictly to NFPA 72 standards, ensuring reliability and compliance in fire alarm systems. It meets requirements for remote annunciators, including proper installation, wiring, and performance. The device supports necessary functions like alarm acknowledgment and system monitoring, aligning with NFPA guidelines. Regular testing and maintenance procedures are outlined to maintain compliance. By following these standards, the ANN-80 ensures accurate and timely notifications, critical for fire safety. Compliance with NFPA 72 is essential for system certification and operational integrity, making the ANN-80 a trusted component in fire alarm setups.

Compliance and Certifications

The FireLite ANN-80 Series meets rigorous industry standards, including UL and FM certifications, ensuring reliability and safety. Compliance with these standards guarantees optimal performance and regulatory adherence.

9.1 Regulatory Compliance

The FireLite ANN-80 Series adheres to stringent regulatory standards, ensuring compliance with UL (Underwriters Laboratories) and FM (Factory Mutual) certifications. Designed to meet NFPA 72 requirements, these annunciators are engineered to operate within specified voltage and current parameters, ensuring reliable performance in fire alarm systems. Compliance with local and national codes is guaranteed, making the ANN-80 Series a trusted choice for fire safety applications. Regular updates and adherence to industry norms ensure the device remains compliant with evolving safety regulations, providing users with a dependable solution for critical fire alarm systems. This ensures the annunciator functions optimally under all specified conditions.

9.2 Industry Certifications

The FireLite ANN-80 Series holds prestigious industry certifications, including UL and FM approvals, ensuring its reliability and performance in fire safety systems. These certifications validate the device’s ability to meet rigorous industry standards for fire alarm components. The ANN-80 Series is also compliant with NFPA 72 requirements, further solidifying its credibility; Additionally, it is recognized by major fire safety organizations, making it a preferred choice for professionals. These certifications assure users of the product’s quality, safety, and adherence to industry best practices, providing peace of mind in critical fire alarm applications. This recognition underscores Honeywell’s commitment to excellence and reliability in fire protection solutions.

9.3 Compatibility with FACP Systems

The FireLite ANN-80 Series is designed to seamlessly integrate with compatible Fire Alarm Control Panels (FACPs), ensuring enhanced system functionality and coordination. Its compatibility with leading FACP systems allows for real-time data synchronization, enabling accurate monitoring and control. The ANN-80 Series supports advanced communication protocols, facilitating smooth interaction with control panels. This integration ensures that all system statuses, alarms, and troubleshooting data are consistently displayed. Compatibility with FACP systems enhances the overall efficiency of fire safety networks, making the ANN-80 Series a versatile and reliable component in modern fire alarm configurations. This seamless integration is a testament to its robust engineering and design.

The FireLite ANN-80 Series offers reliable fire safety solutions, adhering to NFPA standards and ensuring optimal performance. Proper usage and maintenance are crucial for system longevity and effectiveness.

10.1 Summary of Key Points

The FireLite ANN-80 Series is a robust fire safety solution, offering compact, backlit LCD displays for clear system status monitoring. Designed for compatibility with Fire Alarm Control Panels (FACPs), these annunciators provide detailed point status, custom alpha labels, and zone assignments. The series includes models like ANN-80, ANN-80-W, and ANN-80C, each tailored for specific applications. This manual guides users through installation, configuration, and maintenance, ensuring compliance with NFPA 72 standards. Proper usage and regular upkeep are emphasized to maximize system performance and reliability, making the ANN-80 Series an essential tool for fire safety professionals and facilities adhering to strict regulatory requirements.

10.2 Importance of Proper Usage and Maintenance

Proper usage and maintenance of the FireLite ANN-80 Series are crucial for ensuring reliable fire safety monitoring. Following the guidelines outlined in this manual prevents system malfunctions and extends the product lifespan. Regular cleaning of the LCD display and updating firmware guarantee optimal performance. Adherence to NFPA 72 standards and manufacturer recommendations ensures compliance and safety. Neglecting maintenance can lead to false alarms or undetected issues, compromising fire safety. By prioritizing proper care, users ensure the ANN-80 Series functions effectively, providing critical alerts and maintaining trust in the system’s integrity for safeguarding people and property.

10.3 Resources for Further Assistance

For additional support, refer to the official FireLite website or contact Honeywell’s customer service at 1-800-328-0103. The Notifier website also offers detailed resources and FAQs. Download the PDF manual from trusted sources like firelite.com or honeywell.com. For technical inquiries, email techsupport@honeywell.com. Visit community forums or professional fire safety groups for peer advice. Ensure compliance by consulting local fire codes and NFPA standards. Regular firmware updates and maintenance guides are available on the FireLite portal. These resources ensure optimal performance and compliance with safety regulations.